doodlesuite
A newly fitted en suite shower room with a glass shower enclosure, a white basin and toilet, and an extractor fan high on the wall near the ceiling
AI-generated image, not a photograph of a real person or place.

WHAT THE GUIDANCE SAYS

A new en suite,
built to the rules.

Installing a bathroom that involves plumbing is one of the jobs that may need building regulations approval.

England's Approved Documents set out how to meet the rules: enough extraction to clear steam, a place to wash hands by every WC, a door between any WC and the kitchen, and limits on bath water temperature in new homes.

15 l/s intermittent extract for a bathroom

Check a feature

THE SHORT ANSWER

Check approval,
then plan the details.

Building regulations approval is different from planning permission.
You might need both.

VENTILATION

A fan that keeps up

Approved Document F gives a minimum intermittent extract rate of 15 l/s for a bathroom. With no openable window, the fan should run on for at least 15 minutes after you leave.

See the numbers

APPROVAL

New plumbing counts

GOV.UK lists installing a bathroom that will involve plumbing among jobs that may need approval. Using a registered competent person scheme installer means you do not need to get approval yourself.

Check a feature

HYGIENE

A basin by every WC

Every extra toilet should have its own hand washing facility, in the same room or in an adjacent space that is the only way in.

Plan the room
A wall-mounted white washbasin with a mixer tap beside a toilet in a compact en suite
AI-generated image, not a photograph of a real person or place.

FOUR THINGS TO PLAN

Plan it on paper
before the pipes go in.

A simple order of questions to raise with your builder or building control body, based on GOV.UK and the Approved Documents.

  1. Ask about approval

    Check whether your work needs building regulations approval, or use an installer registered with a competent person scheme.

  2. Plan the extraction

    Allow for a fan at 15 l/s, mounted high, with a 15-minute run-on if the room has no openable window.

  3. Let air move

    Internal doors should allow air to pass, equivalent to a 10 mm undercut on a 760 mm wide door.

  4. Place the basin and doors

    Put a hand basin in the WC room or its only way in, and keep a door between the WC and any kitchen.

TWO NUMBERS WORTH KNOWING

One for the steam,
one for the bath.

Both figures come straight from
England's Approved Documents.

15 l/s

Minimum intermittent extract rate for a bathroom

Table 1.1 sets 15 litres a second for a bathroom, 6 for a room with only a WC. Fans should sit as high as practicable, no more than 400 mm below the ceiling.

VENTILATION · APPROVED DOCUMENT F

48°C

Maximum temperature of water delivered to a fixed bath

Requirement G3(4) says the hot supply to any fixed bath must not deliver water above 48°C, in new dwellings and those formed by a material change of use.

HOT WATER · APPROVED DOCUMENT G

When a kitchen or bathroom is refurbished, Approved Document F says any existing extractor fans should be retained or replaced, and checked to see they work properly.

A QUICK FEATURE CHECK

What do the rules
say about this?

Pick a feature of your en suite to see what England's building regulations guidance says. The bar shows how widely the point applies to an en suite added to an existing home.

Feature check

Choose a feature
Extractor fan15 l/s intermittent

For a new wet room, extract ventilation should be added: an intermittent fan at the Table 1.1 rate plus a background ventilator of at least 5,000 mm², or continuous extract.

Hand basinIn or next to the WC room

Hand washing facilities must be in the room with the WC, or in an adjacent space that is the only way into it, and not used for preparing food.

Door near a kitchenKeep a door between

A WC or its hand basin should be separated by a door from any kitchen or food preparation area.

New plumbingApproval may be needed

Installing a bathroom that involves plumbing may need building regulations approval. Check with a building control body if unsure.

Hot water to a bath48°C cap in new homes

The 48°C limit on water delivered to a fixed bath applies when a dwelling is newly built or formed by a material change of use, not to every refit.

Source: GOV.UK, Building regulations approval; Approved Document F, Volume 1: Dwellings; Approved Document G (2015 edition with 2016 and 2024 amendments). This is a summary, not professional building advice.

From GOV.UK and Approved Documents F (ventilation, dwellings) and G (sanitation and hot water safety), England.

A white ceiling-mounted extractor fan grille in a bathroom, with light steam drifting from a shower below
AI-generated image, not a photograph of a real person or place.

WHY IT MATTERS

Certificates count
when you sell.

GOV.UK warns that the person doing the work could be prosecuted and fined if building regulations are not followed, and the building control body could make you pay to fix faulty work.

Without approval, you will not have the certificates of compliance you may need when you come to sell your home. Swapping an extractor fan on existing cabling, Approved Document F notes, does not need to be notified.

Questions

Questions people ask

Do I need building regulations approval for an en suite?

You might. GOV.UK lists installing a bathroom that will involve plumbing among the projects that may need approval. Check with a building control body if you cannot decide.

How powerful should a bathroom extractor fan be?

Approved Document F gives a minimum intermittent extract rate of 15 litres per second for a bathroom, with a 15-minute run-on where there is no openable window.

Does an en suite need its own basin?

Approved Document G says each additional toilet should have an associated hand washing facility, in the same room or an adjacent space that is the only way in.

Can a toilet open straight onto a kitchen?

A room with a WC or its hand basin should be separated from any kitchen or food preparation area by a door. In homes, a room with both a WC and a basin does not need a separate lobby.

Is there a limit on bath water temperature?

For new dwellings and those formed by a material change of use, the hot supply to a fixed bath must not deliver water above 48°C.

Sources

  1. GOV.UK: Building regulations approval, when you need approval
  2. GOV.UK: Ventilation, Approved Document F
  3. GOV.UK: Sanitation, hot water safety and water efficiency, Approved Document G
  4. Approved Document G with 2024 amendments (PDF)

Updated

ABOUT THIS NAME

doodlesuite.com could be yours.

doodlesuite.com is part of the DoodleSale portfolio. Check the current listing and available purchase or lease options.

Explore this domain